Band
Reject Data
Sheets (Examples) on PDF Pages: |
Band Reject
Normal Slopes |
 |
 |
Band Reject Filters
(Cavity Design)
G-Series = Normal Slopes
Reject Bands between 1698 MHz and 1910 MHz |
|
Open
Data
Sheet
(40 - 50 KB) |
Reject Band
in MHz |
Slope &
minimum
Attenuation |
Pass
Band
in MHz |
Max. Loss |
Internal
Ref. No.: |
|
in
Passband |
at
Corners |
|
 |
1698 - 1710 |
34 MHz
90 dB |
DC to
4000 |
1.0 dB |
1.5 dB
1664/1744 |
RCG 1710
-90/5EX |
|
 |
1709 - 1786 |
20 MHz
40 dB |
DC to
3600 |
1.0 dB |
1.5 dB
1689/1806 |
RCG 1786
-40/8EX |
|
 |
1709 - 1786 |
10 MHz
40 dB |
DC to
3300 |
1.0 dB |
2.0 dB
1699/ 1796 |
RCG 1786
-40/11EX |
|
 |
1709 - 1786 |
10 MHz
50 dB |
DC to
3300 |
1.0 dB |
3.0 dB
1699/1796 |
RCG 1786
-50/12EX |
|
 |
1710 - 1725 |
20 MHz
60 dB |
DC to
3300 |
1.0 dB |
1.5 dB
1690/1745 |
RCG 1725
-60/7EX |
|
 |
1710 - 17 55 |
20 MHz
90 dB |
DC to
3300 |
1.5 dB |
3.0 dB
1690/1 775 |
RCG 1755
-90/14EX |
|
 |
1710 - 1785 |
20 MHz
25 dB |
DC to
3300 |
0.7 dB |
1.0 dB
1690/1805 |
RCG 1785
-25/5EX |
|
 |
1710 - 1785 |
30MHz / 20MHz
35 dB |
DC to
3600 |
0.7 dB |
1.0 dB
1680/1805 |
RCG 1785
-35/8EX |
|
 |
1710 - 1785 |
20
MHz
60 dB |
DC to
3300 |
1.0 dB |
3.0 dB
1690/1805 |
RCG 1785
-60/12EX |
|
 |
1737
- 17 43 |
4MHz
40 dB |
DC to
3600 |
1.2 dB |
2.5 dB
1733/ 1747 |
RCG
1743
-40/6EX |
|
 |
1740 - 1755 |
15 MHz
20 dB |
DC to
3600 |
0.6 dB |
1.0 dB
1725/1770 |
RCG 1755
-20/5EX |
|
 |
1744.4
- 17 50.4 |
6
MHz
40 dB |
DC to
3600 |
1.2 dB |
1.5 dB
1738.4/ 1756.4 |
RCG
1750.4
-40/6EX |
|
 |
1749.9
- 17 84.9 |
20MHz
90 dB |
DC to
3300 |
1.5 dB |
3.0 dB
1730/1805 |
RCG 1784.9
-90/14EX |
|
 |
1764.4
- 17 70.4 |
4
MHz
40 dB |
DC to
3600 |
1.2 dB |
2.5 dB
1760.4/ 1774.4 |
RCG
1770.4
-40/6EX |
|
 |
1805 - 18 65 |
20/15 MHz
60 dB |
DC to
3600 |
1.5 dB |
2.0 dB
1785/1880 |
RCG 1865
-60/16EX |
|
 |
1805 - 1880 |
20 MHz
20 dB |
DC to
3300 |
1.0 dB |
1.2 dB
1785/1900 |
RCG 1880
-20/6EX |
|
 |
1805 - 1880 |
30 MHz
30 dB |
DC to
3600 |
1.5 dB |
2.0 dB
1775/1910 |
RCG 1880
-30/7EX |
|
 |
1805 - 1880 |
20 MHz
40 dB |
DC to
3300 |
1.0 dB |
1.2 dB
1785/1900 |
RCG 1880
-40/9EX |
|
 |
1805 - 1880 |
20 MHz
50 dB |
DC to
3300 |
1.0 dB |
1.5 dB
1785/1900 |
RCG 1880
-50/10EX |
|
 |
1805 - 1880 |
20 MHz
80 dB |
DC to
3300 |
1.0 dB |
2.5 dB
1785/1900 |
RCG 1880
-80/14EX |
|
 |
1805 - 1880 |
20 MHz
90 dB |
DC to
3300 |
1.5 dB |
2.5 dB
1785/1900 |
RCG 1880
-90/16EX |
|
 |
1850 - 1910 |
20 MHz
35 dB |
DC to
4000 |
1.0 dB |
1.5 dB
1830/1930 |
RCG 1910
-35/8EX |
|
 |
1850 - 1910 |
15 MHz
40 dB |
DC to
4000 |
1.5 dB |
2.5 dB
1835/1925 |
RCG 1910
-40/8EX |
|
 |
1850 - 1910 |
20 MHz
60 dB |
DC to
3600 |
1.0 dB |
2.0 dB
1830/1930 |
RCG 1910
-60/10EX |
|
 |
1850 - 1910 |
16 MHz
60 dB |
DC to
4000 |
1.5 dB |
2.25 dB
1834/1926 |
RCG 1910
-60/11EX |
|
 |
1850 - 1910 |
30 MHz
75 dB |
DC to
3300 |
1.0 dB |
1.5 dB
1820/ 1940 |
RCG 1910
-75/12EX |
|
 |
1850 - 1910 |
16 MHz
80 dB |
DC to
3300 |
1.5 dB |
3.0 dB
1834/1926 |
RCG 1910
-80/14EX |
|
 |
1875 - 1885 |
10 MHz
20 dB |
DC to
3300 |
1.0 dB |
1.5 dB
1865/1895 |
RCG 1885
-20/4EX |
|
 |
1877
- 188 3 |
7 MHz
40 dB |
DC to
3600 |
1.2 dB |
1.5 dB
1870/ 1890 |
RCG 1883
-40/6EX |
|
 |
Quotation Request Forms
If you did not find a suitable filter on
the list above,
please let us have your Request for Quotation. |
qr-br-cav |
Wainwright Instruments GmbH - Band Reject Filters G-Series = Normal Slopes
G2 -L3-
updated