Lowpass

High Power Handling

Lowpass  Filters for High  Power Handling

Fco between 25 MHz and 1800 MHz

Open
PDF
Data
Sheet

Max.
Power
Handling
in
Passband

Pass
Band

Max.
Loss in Passband
and at
Fco

Minimum
Reject Attenuation

Stopband Limit
dB min.

Return Loss
measured
at the
worst point

Internal
Ref. No.

40 dB at
MHz:

60 dB at
MHz:


46 kB

1 kW

DC to
55 MHz

0.4 dB

71.5 MHz

79.75 MHz

60 dB

to at least

1000 MHz

17 dB
min.

LF 55-6-
EX-1000W

40 kB

1 kW

DC to
100 MHz

0.4 dB

130 MHz

145 MHz

60 dB

to at least

1000 MHz

17 dB
min.

LF 100-6-
EX-1000W

45 kB

1 kW

DC to
125 MHz

0.4 dB

162.5 MHz

181.25 MHz

60 dB

to at least

1000 MHz

17 dB
min.

LF 125-6-
EX-1000W

37 kB

1 kW

DC to
135 MHz

0.4 dB

156.6 MHz

164.7 MHz

60 dB

to at least

2300 MHz

17 dB
min.

LF 135FB-10-
EX-1000W

49 kB

1 kW

DC to
191 MHz

0.4 dB

221.6 MHz

233.0 MHz

60 dB

to at least

2300 MHz

17 dB
min.

LF 191FB-
10-EX-1000W

48 kB

1 kW

DC to
300 MHz

0.45 dB

348 MHz

366 MHz

60 dB

to at least

2000 MHz

17 dB
min.

LF 300FB-10-
EX-1000W

48 kB

300 W

DC to
420 MHz

0.17 dB

907.2 MHz

1228.5 MHz

60 dB

to at least

2500 MHz

14 dB
min.

WLG 420-3-
EX-300W

39 kB

1 kW

DC to
425 MHz

0.3 dB

552.5 MHz

616.25 MHz

60 dB

to at least

2800 MHz

17 dB
min.

LF 425-6-
EX-1000W

71 kB

1 kW

DC to
500 MHz

0.45 dB

580 MHz

610 MHz

60 dB

to at least

3000 MHz

17 dB
min.

LG 500FB-
10-EX-1000W

42 kB

500 W

DC to
560 MHz

0.3 dB

728 MHz

812 MHz

60 dB

to at least

3500 MHz

17 dB
min.

LG 560-6-
EX-500W

41 kB

1 kW

DC to
560 MHz

0.3 dB

728 MHz

812 MHz

60 dB

to at least

3500 MHz

17 dB
min.

LF 560-6-
EX-1000W

74 kB

500 W

DC to
800 MHz

0.3 dB

1040 MHz

1160 MHz

60 dB

to at least

3500 MHz

17 dB
min.

LG 800-6-
EX-500w

41 kB

1 kW

DC to
800 MHz

0.3 dB

1040 MHz

1160 MHz

60 dB

to at least

3500 MHz

17 dB
min.

LF 800-6-
EX-1000W

73 kB

500 W

DC to
1000 MHz

0.3 dB

1300 MHz

1450 MHz

60 dB

to at least

3500 MHz

17 dB
min.

LG 1000-6-
EX-500W

41 kB

1 kW

DC to
1000 MHz

0.3 dB

1300 MHz

1450 MHz

60 dB

to at least

3500 MHz

17 dB
min.

LF 1000-6-
EX-1000W

49 kB

100 W

DC to
1..8 GHz

0.3 dB

1.53 ..
12.24
GHz

1.95 ..
15.6
GHz

60 dB

to at least

5..17 GHz

20 dB
typ.

LPJ1 to 8GHz
 

Terminated Lowpass Filter - with Matched Stopband
Continuous Return Loss from DC to 350 MHz

 
 

Max.
Power
Handling
in
Passband

Fco/
Pass
Band

Max.
Loss in Passband
and at
Fco

Minimum
Reject Attenuation

Return Loss
measured
at the
worst point

Internal
Ref. No.

40 dB at
MHz:

60 dB at
MHz:

80 dB at
MHz:


56 kB

1 kW

DC to

25 MHz

0.5 dB

31.0

32.5

34.5

14 dB
min.

LE25-9/8 Term-EX-1000W

60 kB

500 W

DC to

30 MHz

0.5 dB

50 dB at 33 MHz
Cauer Design

14 dB
min.

LE30-C11/4 Term-EX-500W