Standard High Pass Filters

Here is a list of our standard LC high pass filters in Chebyshev or Cauer (elliptic) design, with guaranteed specifications
and prices. After entering your required passband cut-off frequency (Fco) and choosing your other requirements, you can
generate a data sheet with a valid model number, price, mechanical drawings and a summary of all your specifications. For
help on these functions please click on the "Help" button. If you don't find high pass filters here that match your needs,
please send us a quotation request for custom high pass filters.

Displaying results 871 to 882 out of 882

<< First

< Previous

601-630

631-660

661-690

691-720

721-750

751-780

781-810

811-840

841-870

871-882

Next >

Last >>

Any
Fco
Within:
(MHz)
Max.
IL in
Passb.
(dB)
Max.
IL at
Corner
(dB)
Min.
Return
Loss
(dB)
Min.
Stopb.
Atten.
(dB)
Max.
Slopes
(MHz)
Min.
Passb.
Limit
(MHz)
Max.
CW
Power
(W)
 
Approximate
Dimensions
(L x W x H)
 
 
Approx.
Weight
 
 
Price
(EUR)
 
 
Data
Sheet
20500 to 20999 0.6 0.75 12 40 0.240 x Fco 39000 30 60 x 20 x 12 0.08 1290
21000 to 21499 0.6 0.75 12 40 0.240 x Fco 40000 30 60 x 20 x 12 0.08 1290
21500 to 21999 0.6 0.75 12 40 0.240 x Fco 40000 30 60 x 20 x 12 0.08 1290
22000 to 22499 0.6 0.75 12 40 0.230 x Fco 40000 30 60 x 20 x 12 0.08 1290
22500 to 22999 0.6 0.75 12 40 0.230 x Fco 40000 30 60 x 20 x 12 0.08 1290
23000 to 23499 0.6 0.75 12 40 0.230 x Fco 40000 30 60 x 20 x 12 0.08 1290
23500 to 23999 0.6 0.75 12 40 0.230 x Fco 40000 30 60 x 20 x 12 0.08 1290
24000 to 24499 0.6 0.75 12 40 0.220 x Fco 40000 30 60 x 20 x 12 0.08 1290
24500 to 24999 0.6 0.75 12 40 0.220 x Fco 40000 30 60 x 20 x 12 0.08 1290
25000 to 25499 0.6 0.75 12 40 0.220 x Fco 40000 30 60 x 20 x 12 0.08 1290
25500 to 25999 0.6 0.75 12 40 0.220 x Fco 40000 30 60 x 20 x 12 0.08 1290
26000 to 27000 0.6 0.75 12 40 0.210 x Fco 40000 30 60 x 20 x 12 0.08 1290

Displaying results 871 to 882 out of 882

<< First

< Previous

601-630

631-660

661-690

691-720

721-750

751-780

781-810

811-840

841-870

871-882

Next >

Last >>

Standard Highpass Filter List

This list contains many of our standard highpass filters, as well as guaranteed specifications and prices for these. Each
row represents a particular filter and by entering or selecting your required specifications, you will remove those filters from
the list that don't meet or exceed your requirements. Apart from selecting various filter specifications, you can also choose
to have dimensions and weight displayed in the metric or the imperial system. This choice will also be reflected on the
datasheet that is generated. Lastly, you can also choose your required quantity, which will display the respective unit price.

Should you not find a match for your requirements, please use our custom filter forms to enter your specifications and to
request a quotation.


We recommend to proceed as follows:

1) Enter your required Fco (passband cutoff frequency) in the field where it says "Enter Fco" and click . Now only filters
that can be offered with your required Fco will remain in the list.

2) One by one, select your other required specifications from the drop-down menus at the top of the list. As you select more
specs, the list of filters will continually shrink until you are left with a single or very few relevant filters to choose from.

3) Click on the far right of any row to view that filter's datasheet. On the datasheet itself you will still be able to adjust
your Fco - if necessary - and select your preferred connectors. You can either print out the datasheet or generate a PDF for
saving or emailing. You may also generate a quote request directly from the datasheet by adding the quantity required to
the Quote Basket and filling out the contact form located there.